Dây nhảy quang MM,LC-LC, Duplex

Giá: Call

Mã SP: MM,LC-LC

Tính năng:

 

LC/LC Fiber optic patchcord Duplex 
 
Description
LC/LC FIBER OPTIC JUMPERS are ultra reliable components featuring low insertion loss and high return loss. They come with your choice of simplex or duplex cable configuration and are made to conform to IEC,Telcordia GR-326-CORE Standard.
Envronmental Reliability Test
The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others
Key Features
Low insertion loss
high return loss
Various connector types available
Easy instalation
Environmentally stable
Applications
Fiber Optic Telecommunications
LAN (Local Area Network
FTTH (Fiber To The Home)
CATV&CCTV
High speed transmission systems
Fiber optic sensing
Specifications
Type
Standard,Master
Style
LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC 
Duplex MTRJ/Female, MTRJ/Male FIBER PATCH CORD OR FIBER OPTIC PATCH CORD OR FIBEROPTIC CABLE
Fiber Type
 
9/125 SMF-28 or equivalent (Singlemade) OS1
50/125, 62.5/125 (Multimode) OM2&OM1
50/125, 10G (Multimode) OM3
Fiber Cable Type
Simplex, Duplex (Zipcord)
Φ3.0mm, Φ2.0mm, Φ1.8mm
Φ1.6mm PVC or LSZH
Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH
Polishing Manner
UPC,SPC,APC (8°& 6°)
Insertion Loss
≤ 0.1dB (For Singlemode Master)
≤ 0.25dB (For Singlemode Standard)
≤ 0.25dB (For Multimode)
Tested by JDS RM 3750
Return Loss
(For Singlemode)
UPC ≥ 50dB
SPC ≥ 55dB
APC ≥ 60dB (typ.65dB)
Tested by JDS RM3750
Repeatability
 
±0.1dB
Operating temperature
-400C to 850C
Geometry Requirement
(For Singlemode)
Ferrule Endface Radius
7mm ≤ R ≤ 12mm (For APC)
10mm ≤ R ≤ 25mm (For Standard)
Apex Offset ≤ 30 μm (For Master)
Apex Offset ≤ 50 μm (For Standard)
Undercut -50nm ≤ U ≤ 50nm
Tested by DORC ZX-1

Dây nhảy quang MM,LC-LC, Duplex

Dây nhảy quang MM,SC-SC, Duplex

Giá: Call

Mã SP: MM,SC-SC

Tính năng:

 

Detailed Product Description
 
SC/SC Fiber patch cord, Duplex
 
Description
Fiber optic Patch cords are ultra reliable components featuring low insertion loss and return loss. They come with your choice of si mplex or duplex cable configuration and are made to conform to IEC,Telcordia GR-326-CORE Standard.
Environmental Reliability Test
The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others
Applications
Fiber Optic Telecommunications
LAN (Local Area Network
FTTH (Fiber To The Home)
CATV&CCTV
High speed transmission systems
Fiber optic sensing
Specifications
Type
Standard,Master
Style
LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC 
Duplex MTRJ/Female, MTRJ/Male
Fiber Type
 
9/125 SMF-28 or equivalent (Singlemade) OS1
50/125, 62.5/125 (Multimode) OM2&OM1
50/125, 10G (Multimode) OM3
Cable Type
Simplex, Duplex (Zipcord)
Φ3.0mm, Φ2.0mm, Φ1.8mm
Φ1.6mm PVC or LSZH
Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH
Polishing Manner
UPC,SPC,APC (8°& 6°)
Insertion Loss
≤ 0.1dB (For Singlemode Master)
≤ 0.25dB (For Singlemode Standard)
≤ 0.25dB (For Multimode)
Tested by JDS RM 3750
Return Loss
(For Singlemode)
UPC ≥ 50dB
SPC ≥ 55dB
APC ≥ 60dB (typ.65dB)
Tested by JDS RM3750
Repeatability
 
±0.1dB
Operating temperature
-400C to 850C
Geometry Requirement
(For Singlemode)
Ferrule Endface Radius
7mm ≤ R ≤ 12mm (For APC)
10mm ≤ R ≤ 25mm (For Standard)
Apex Offset ≤ 30 μm (For Master)
Apex Offset ≤ 50 μm (For Standard)
Undercut -50nm ≤ U ≤ 50nm
Tested by DORC ZX-1

Dây nhảy quang MM,SC-SC, Duplex

Dây nhảy quang MM,SC-LC, Duplex

Giá: Call

Mã SP: MM,SC-LC

Tính năng:

 

Detailed Product Description
 
SC/LC Fiber optic patchcord Duplex
 
Description
SC/LC FIBER OPTIC JUMPERS are ultra reliable components featuring low insertion loss and high return loss. They come with your choice of simplex or duplex cable configuration and are made to conform to IEC,Telcordia GR-326-CORE Standard.
Envronmental Reliability Test
The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others
Key Features
Low insertion loss
high return loss
Various connector types available
Easy instalation
Environmentally stable
Applications
Fiber Optic Telecommunications
LAN (Local Area Network
FTTH (Fiber To The Home)
CATV&CCTV
High speed transmission systems
Fiber optic sensing
Specifications
Type
Standard,Master
Style
LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC 
Duplex MTRJ/Female, MTRJ/Male FIBER PATCH CORD OR FIBER OPTIC PATCH CORD OR FIBEROPTIC CABLE
Fiber Type
 
9/125 SMF-28 or equivalent (Singlemade) OS1
50/125, 62.5/125 (Multimode) OM2&OM1
50/125, 10G (Multimode) OM3
Fiber Cable Type
Simplex, Duplex (Zipcord)
Φ3.0mm, Φ2.0mm, Φ1.8mm
Φ1.6mm PVC or LSZH
Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH
Polishing Manner
UPC,SPC,APC (8°& 6°)
Insertion Loss
≤ 0.1dB (For Singlemode Master)
≤ 0.25dB (For Singlemode Standard)
≤ 0.25dB (For Multimode)
Tested by JDS RM 3750
Return Loss
(For Singlemode)
UPC ≥ 50dB
SPC ≥ 55dB
APC ≥ 60dB (typ.65dB)
Tested by JDS RM3750
Repeatability
 
±0.1dB
Operating temperature
-400C to 850C
Geometry Requirement
(For Singlemode)
Ferrule Endface Radius
7mm ≤ R ≤ 12mm (For APC)
10mm ≤ R ≤ 25mm (For Standard)
Apex Offset ≤ 30 μm (For Master)
Apex Offset ≤ 50 μm (For Standard)
Undercut -50nm ≤ U ≤ 50nm
Tested by DORC ZX-1

Dây nhảy quang MM,SC-LC, Duplex

Dây Pigtail ST, Multimode

Giá: Call

Mã SP: Pigtail ST

Tính năng:

 

Detailed Product Description
 
FC SC LC ST optic fiber pigtail
Description
Single mode pigtail
Available in: SPC (Super Physical Contact), UPC (Ultra Physical Contact) or APC (Angled Physical Contact)
Fiber type: G652.D, G655 and G657.A
Construction of secondary protection: tight or loose 
Available in 12 colours of primary and secondary protection
Multi mode pigtail
Fiber types: OM1, OM2 and OM3
Construction of secondary protection: tight or loose 
Available in 12 colours of primary and secondary protection
Environmental Reliability Test
The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others
Key Features
Low insertion loss
Low return loss
Various connector types available
Easy instalation
Environmentally stable
Applications
Fiber Optic Telecommunications
LAN (Local Area Network
FTTH (Fiber To The Home)
CATV&CCTV
High speed transmission systems
Fiber optic sensing
Specifications
Type
Standard,Master
Style
LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC 
Duplex MTRJ/Female, MTRJ/Male
Fiber Type
 
9/125 SMF-28 or equivalent (Singlemade) OS1
50/125, 62.5/125 (Multimode) OM2&OM1
50/125, 10G (Multimode) OM3
Cable Type
Simplex, Duplex (Zipcord)
Φ3.0mm, Φ2.0mm, Φ1.8mm
Φ1.6mm PVC or LSZH
Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH
Polishing Manner
UPC,SPC,APC (8°& 6°)
Insertion Loss
≤ 0.1dB (For Singlemode Master)
≤ 0.25dB (For Singlemode Standard)
≤ 0.25dB (For Multimode)
Tested by JDS RM 3750
Return Loss
(For Singlemode)
UPC ≥ 50dB
SPC ≥ 55dB
APC ≥ 60dB (typ.65dB)
Tested by JDS RM3750
Repeatability
 
±0.1dB
Operating temperature
-400C to 850C
Geometry Requirement
(For Singlemode)
Ferrule Endface Radius
7mm ≤ R ≤ 12mm (For APC)
10mm ≤ R ≤ 25mm (For Standard)
Apex Offset ≤ 30 μm (For Master)
Apex Offset ≤ 50 μm (For Standard)
Undercut -50nm ≤ U ≤ 50nm
Tested by DORC ZX-1

Dây Pigtail ST, Multimode

Dây Pigtail LC, Singlemode

Giá: Call

Mã SP: Pigtail LC

Tính năng:

 

Detailed Product Description
LC fiber optic pigtail
Description
Single mode pigtail
Available in: SPC (Super Physical Contact), UPC (Ultra Physical Contact) or APC (Angled Physical Contact)
Fiber type: G652.D, G655 and G657.A
Construction of secondary protection: tight or loose 
Available in 12 colours of primary and secondary protection
Multi mode pigtail
Fiber types: OM1, OM2 and OM3
Construction of secondary protection: tight or loose 
Available in 12 colours of primary and secondary protection
Environmental Reliability Test
The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others
Key Features
Low insertion loss
Low return loss
Various connector types available
Easy instalation
Environmentally stable
Applications
Fiber Optic Telecommunications
LAN (Local Area Network
FTTH (Fiber To The Home)
CATV&CCTV
High speed transmission systems
Fiber optic sensing
Specifications
Type
Standard,Master
Style
LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC 
Duplex MTRJ/Female, MTRJ/Male
Fiber Type
 
9/125 SMF-28 or equivalent (Singlemade) OS1
50/125, 62.5/125 (Multimode) OM2&OM1
50/125, 10G (Multimode) OM3
Cable Type
Simplex, Duplex (Zipcord)
Φ3.0mm, Φ2.0mm, Φ1.8mm
Φ1.6mm PVC or LSZH
Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH
Polishing Manner
UPC,SPC,APC (8°& 6°)
Insertion Loss
≤ 0.1dB (For Singlemode Master)
≤ 0.25dB (For Singlemode Standard)
≤ 0.25dB (For Multimode)
Tested by JDS RM 3750
Return Loss
(For Singlemode)
UPC ≥ 50dB
SPC ≥ 55dB
APC ≥ 60dB (typ.65dB)
Tested by JDS RM3750
Repeatability
 
±0.1dB
Operating temperature
-400C to 850C
Geometry Requirement
(For Singlemode)
Ferrule Endface Radius
7mm ≤ R ≤ 12mm (For APC)
10mm ≤ R ≤ 25mm (For Standard)
Apex Offset ≤ 30 μm (For Master)
Apex Offset ≤ 50 μm (For Standard)
Undercut -50nm ≤ U ≤ 50nm
Tested by DORC ZX-1

Dây Pigtail LC, Singlemode

Dây Pigtail FC, Singlemode

Giá: Call

Mã SP: Pigtail FC

Tính năng:

 

Detailed Product Description
 
 
FC fiber optic pigtails
Description
Single mode pigtails
Available in: SPC (Super Physical Contact), UPC (Ultra Physical Contact) or APC (Angled Physical Contact)
Fiber type: G652.D, G655 and G657.A
Construction of secondary protection: tight or loose 
Available in 12 colours of primary and secondary protection
Multi mode pigtails
Fiber types: OM1, OM2 and OM3
Construction of secondary protection: tight or loose 
Available in 12 colours of primary and secondary protection
Environmental Reliability Test
The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others
Key Features
Low insertion loss
Low return loss
Various connector types available
Easy instalation
Environmentally stable
Applications
Fiber Optic Telecommunications
LAN (Local Area Network
FTTH (Fiber To The Home)
CATV&CCTV
High speed transmission systems
Fiber optic sensing
Specifications
Type
Standard,Master
Style
LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC 
Duplex MTRJ/Female, MTRJ/Male
Fiber Type
 
9/125 SMF-28 or equivalent (Singlemade) OS1
50/125, 62.5/125 (Multimode) OM2&OM1
50/125, 10G (Multimode) OM3
Cable Type
Simplex, Duplex (Zipcord)
Φ3.0mm, Φ2.0mm, Φ1.8mm
Φ1.6mm PVC or LSZH
Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH
Polishing Manner
UPC,SPC,APC (8°& 6°)
Insertion Loss
≤ 0.1dB (For Singlemode Master)
≤ 0.25dB (For Singlemode Standard)
≤ 0.25dB (For Multimode)
Tested by JDS RM 3750
Return Loss
(For Singlemode)
UPC ≥ 50dB
SPC ≥ 55dB
APC ≥ 60dB (typ.65dB)
Tested by JDS RM3750
Repeatability
 
±0.1dB
Operating temperature
-400C to 850C
Geometry Requirement
(For Singlemode)
Ferrule Endface Radius
7mm ≤ R ≤ 12mm (For APC)
10mm ≤ R ≤ 25mm (For Standard)
Apex Offset ≤ 30 μm (For Master)
Apex Offset ≤ 50 μm (For Standard)
Undercut -50nm ≤ U ≤ 50nm
Tested by DORC ZX-1

Dây Pigtail FC, Singlemode

Dây Pigtail SC, Singlemode

Giá: Call

Mã SP: Pigtail SC

Tính năng:

 

Detailed Product Description
SC fiber optic pigtails
 
Description
Single mode pigtails
Available in: SPC (Super Physical Contact), UPC (Ultra Physical Contact) or APC (Angled Physical Contact)
Fiber type: G652.D, G655 and G657.A
Construction of secondary protection: tight or loose 
Available in 12 colours of primary and secondary protection
Multi mode pigtails
Fiber types: OM1, OM2 and OM3
Construction of secondary protection: tight or loose 
Available in 12 colours of primary and secondary protection
Environmental Reliability Test
The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others
Key Features
Low insertion loss
Low return loss
Various connector types available
Easy instalation
Environmentally stable
Applications
Fiber Optic Telecommunications
LAN (Local Area Network
FTTH (Fiber To The Home)
CATV&CCTV
High speed transmission systems
Fiber optic sensing
Specifications
Type
Standard,Master
Style
LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC 
Duplex MTRJ/Female, MTRJ/Male
Fiber Type
 
9/125 SMF-28 or equivalent (Singlemade) OS1
50/125, 62.5/125 (Multimode) OM2&OM1
50/125, 10G (Multimode) OM3
Cable Type
Simplex, Duplex (Zipcord)
Φ3.0mm, Φ2.0mm, Φ1.8mm
Φ1.6mm PVC or LSZH
Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH
Polishing Manner
UPC,SPC,APC (8°& 6°)
Insertion Loss
≤ 0.1dB (For Singlemode Master)
≤ 0.25dB (For Singlemode Standard)
≤ 0.25dB (For Multimode)
Tested by JDS RM 3750
Return Loss
(For Singlemode)
UPC ≥ 50dB
SPC ≥ 55dB
APC ≥ 60dB (typ.65dB)
Tested by JDS RM3750
Repeatability
 
±0.1dB
Operating temperature
-400C to 850C
Geometry Requirement
(For Singlemode)
Ferrule Endface Radius
7mm ≤ R ≤ 12mm (For APC)
10mm ≤ R ≤ 25mm (For Standard)
Apex Offset ≤ 30 μm (For Master)
Apex Offset ≤ 50 μm (For Standard)
Undercut -50nm ≤ U ≤ 50nm
Tested by DORC ZX-1

Dây Pigtail SC, Singlemode

Dây nhảy quang Multimode SC-SC, Simplex

Giá: Call

Mã SP: Multimode SC-SC

Tính năng:

 

Detailed Product Description
 
SC Fiber patch cord 
 
Description
Fiber optic Patch cords are ultra reliable components featuring low insertion loss and return loss. They come with your choice of si mplex or duplex cable configuration and are made to conform to IEC,Telcordia GR-326-CORE Standard.
Environmental Reliability Test
The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others
Applications
Fiber Optic Telecommunications
LAN (Local Area Network
FTTH (Fiber To The Home)
CATV&CCTV
High speed transmission systems
Fiber optic sensing
Specifications
Type
Standard,Master
Style
LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC 
Duplex MTRJ/Female, MTRJ/Male
Fiber Type
 
9/125 SMF-28 or equivalent (Singlemade) OS1
50/125, 62.5/125 (Multimode) OM2&OM1
50/125, 10G (Multimode) OM3
Cable Type
Simplex, Duplex (Zipcord)
Φ3.0mm, Φ2.0mm, Φ1.8mm
Φ1.6mm PVC or LSZH
Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH
Polishing Manner
UPC,SPC,APC (8°& 6°)
Insertion Loss
≤ 0.1dB (For Singlemode Master)
≤ 0.25dB (For Singlemode Standard)
≤ 0.25dB (For Multimode)
Tested by JDS RM 3750
Return Loss
(For Singlemode)
UPC ≥ 50dB
SPC ≥ 55dB
APC ≥ 60dB (typ.65dB)
Tested by JDS RM3750
Repeatability
 
±0.1dB
Operating temperature
-400C to 850C
Geometry Requirement
(For Singlemode)
Ferrule Endface Radius
7mm ≤ R ≤ 12mm (For APC)
10mm ≤ R ≤ 25mm (For Standard)
Apex Offset ≤ 30 μm (For Master)
Apex Offset ≤ 50 μm (For Standard)
Undercut -50nm ≤ U ≤ 50nm
Tested by DORC ZX-1

Dây nhảy quang Multimode SC-SC, Simplex

Dây nhảy quang MM SC-MTRJ, Duplex

Giá: Call

Mã SP: MM SC-MTRJ

Tính năng:

 

Detailed Product Description
 
MTRJ/SC Fiber optic cable 
 
Description
MTRJ/SC FIBER OPTIC JUMPERS are ultra reliable components featuring low insertion loss and high return loss. They come with your choice of simplex or duplex cable configuration and are made to conform to IEC,Telcordia GR-326-CORE Standard.
Envronmental Reliability Test
The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others
Key Features
Low insertion loss
high return loss
Various connector types available
Easy instalation
Environmentally stable
Applications
Fiber Optic Telecommunications
LAN (Local Area Network
FTTH (Fiber To The Home)
CATV&CCTV
High speed transmission systems
Fiber optic sensing
Specifications
Type
Standard,Master
Style
LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC 
Duplex MTRJ/Female, MTRJ/Male FIBER PATCH CORD OR FIBER OPTIC PATCH CORD OR FIBEROPTIC CABLE
Fiber Type
 
9/125 SMF-28 or equivalent (Singlemade) OS1
50/125, 62.5/125 (Multimode) OM2&OM1
50/125, 10G (Multimode) OM3
Fiber Cable Type
Simplex, Duplex (Zipcord)
Φ3.0mm, Φ2.0mm, Φ1.8mm
Φ1.6mm PVC or LSZH
Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH
Polishing Manner
UPC,SPC,APC (8°& 6°)
Insertion Loss
≤ 0.1dB (For Singlemode Master)
≤ 0.25dB (For Singlemode Standard)
≤ 0.25dB (For Multimode)
Tested by JDS RM 3750
Return Loss
(For Singlemode)
UPC ≥ 50dB
SPC ≥ 55dB
APC ≥ 60dB (typ.65dB)
Tested by JDS RM3750
Repeatability
 
±0.1dB
Operating temperature
-400C to 850C
Geometry Requirement
(For Singlemode)
Ferrule Endface Radius
7mm ≤ R ≤ 12mm (For APC)
10mm ≤ R ≤ 25mm (For Standard)
Apex Offset ≤ 30 μm (For Master)
Apex Offset ≤ 50 μm (For Standard)
Undercut -50nm ≤ U ≤ 50nm
Tested by DORC ZX-1

Dây nhảy quang MM SC-MTRJ, Duplex

Dây nhảy quang Multimode SC-LC, Simplex

Giá: Call

Mã SP: Multimode SC-LC

Tính năng:

 

Detailed Product Description
 
SC/LC Fiber optic cable 
 
Description
SC/LC FIBER OPTIC JUMPERS are ultra reliable components featuring low insertion loss and high return loss. They come with your choice of simplex or duplex cable configuration and are made to conform to IEC,Telcordia GR-326-CORE Standard.
Envronmental Reliability Test
The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others
Key Features
Low insertion loss
high return loss
Various connector types available
Easy instalation
Environmentally stable
Applications
Fiber Optic Telecommunications
LAN (Local Area Network
FTTH (Fiber To The Home)
CATV&CCTV
High speed transmission systems
Fiber optic sensing
Specifications
Type
Standard,Master
Style
LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC 
Duplex MTRJ/Female, MTRJ/Male FIBER PATCH CORD OR FIBER OPTIC PATCH CORD OR FIBEROPTIC CABLE
Fiber Type
 
9/125 SMF-28 or equivalent (Singlemade) OS1
50/125, 62.5/125 (Multimode) OM2&OM1
50/125, 10G (Multimode) OM3
Fiber Cable Type
Simplex, Duplex (Zipcord)
Φ3.0mm, Φ2.0mm, Φ1.8mm
Φ1.6mm PVC or LSZH
Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH
Polishing Manner
UPC,SPC,APC (8°& 6°)
Insertion Loss
≤ 0.1dB (For Singlemode Master)
≤ 0.25dB (For Singlemode Standard)
≤ 0.25dB (For Multimode)
Tested by JDS RM 3750
Return Loss
(For Singlemode)
UPC ≥ 50dB
SPC ≥ 55dB
APC ≥ 60dB (typ.65dB)
Tested by JDS RM3750
Repeatability
 
±0.1dB
Operating temperature
-400C to 850C
Geometry Requirement
(For Singlemode)
Ferrule Endface Radius
7mm ≤ R ≤ 12mm (For APC)
10mm ≤ R ≤ 25mm (For Standard)
Apex Offset ≤ 30 μm (For Master)
Apex Offset ≤ 50 μm (For Standard)
Undercut -50nm ≤ U ≤ 50nm
Tested by DORC ZX-1

Dây nhảy quang Multimode SC-LC, Simplex

Dây nhảy quang Multimode LC-LC, Simplex

Giá: Call

Mã SP: Multimode LC-LC

Tính năng:

 

Detailed Product Description
 
LC/LC Fiber optic cable 
 
Description
LC/LC FIBER OPTIC JUMPERS are ultra reliable components featuring low insertion loss and high return loss. They come with your choice of simplex or duplex cable configuration and are made to conform to IEC,Telcordia GR-326-CORE Standard.
Envronmental Reliability Test
The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others
Key Features
Low insertion loss
high return loss
Various connector types available
Easy instalation
Environmentally stable
Applications
Fiber Optic Telecommunications
LAN (Local Area Network
FTTH (Fiber To The Home)
CATV&CCTV
High speed transmission systems
Fiber optic sensing
Specifications
Type
Standard,Master
Style
LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC 
Duplex MTRJ/Female, MTRJ/Male FIBER PATCH CORD OR FIBER OPTIC PATCH CORD OR FIBEROPTIC CABLE
Fiber Type
 
9/125 SMF-28 or equivalent (Singlemade) OS1
50/125, 62.5/125 (Multimode) OM2&OM1
50/125, 10G (Multimode) OM3
Fiber Cable Type
Simplex, Duplex (Zipcord)
Φ3.0mm, Φ2.0mm, Φ1.8mm
Φ1.6mm PVC or LSZH
Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH
Polishing Manner
UPC,SPC,APC (8°& 6°)
Insertion Loss
≤ 0.1dB (For Singlemode Master)
≤ 0.25dB (For Singlemode Standard)
≤ 0.25dB (For Multimode)
Tested by JDS RM 3750
Return Loss
(For Singlemode)
UPC ≥ 50dB
SPC ≥ 55dB
APC ≥ 60dB (typ.65dB)
Tested by JDS RM3750
Repeatability
 
±0.1dB
Operating temperature
-400C to 850C
Geometry Requirement
(For Singlemode)
Ferrule Endface Radius
7mm ≤ R ≤ 12mm (For APC)
10mm ≤ R ≤ 25mm (For Standard)
Apex Offset ≤ 30 μm (For Master)
Apex Offset ≤ 50 μm (For Standard)
Undercut -50nm ≤ U ≤ 50nm
Tested by DORC ZX-1

Dây nhảy quang Multimode LC-LC, Simplex

Dây nhảy quang Multimode FC-ST, Simplex

Giá: Call

Mã SP: Multimode FC-ST

Tính năng:

 

Detailed Product Description
 
FC/ST Fiber optic patchcord 
 
Description
FC/ST FIBER OPTIC JUMPERS are ultra reliable components featuring low insertion loss and high return loss. They come with your choice of simplex or duplex cable configuration and are made to conform to IEC,Telcordia GR-326-CORE Standard.
Environmental Reliability Test
The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others
Key Features
Low insertion loss
high return loss
Various connector types available
Easy instalation
Environmentally stable
Applications
Fiber Optic Telecommunications
LAN (Local Area Network
FTTH (Fiber To The Home)
CATV&CCTV
High speed transmission systems
Fiber optic sensing
Specifications
Type
Standard,Master
Style
LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC 
Duplex MTRJ/Female, MTRJ/Male FIBER PATCH CORD OR FIBER OPTIC PATCH CORD OR FIBEROPTIC CABLE
Fiber Type
 
9/125 SMF-28 or equivalent (Singlemade) OS1
50/125, 62.5/125 (Multimode) OM2&OM1
50/125, 10G (Multimode) OM3
Fiber Cable Type
Simplex, Duplex (Zipcord)
Φ3.0mm, Φ2.0mm, Φ1.8mm
Φ1.6mm PVC or LSZH
Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH
Polishing Manner
UPC,SPC,APC (8°& 6°)
Insertion Loss
≤ 0.1dB (For Singlemode Master)
≤ 0.25dB (For Singlemode Standard)
≤ 0.25dB (For Multimode)
Tested by JDS RM 3750
Return Loss
(For Singlemode)
UPC ≥ 50dB
SPC ≥ 55dB
APC ≥ 60dB (typ.65dB)
Tested by JDS RM3750
Repeatability
 
±0.1dB
Operating temperature
-400C to 850C
Geometry Requirement
(For Singlemode)
Ferrule Endface Radius
7mm ≤ R ≤ 12mm (For APC)
10mm ≤ R ≤ 25mm (For Standard)
Apex Offset ≤ 30 μm (For Master)
Apex Offset ≤ 50 μm (For Standard)
Undercut -50nm ≤ U ≤ 50nm
Tested by DORC ZX-1

Dây nhảy quang Multimode FC-ST, Simplex

Dây nhảy quang FC/UPC-FC/APC, Simplex 5M

Giá: Call

Mã SP: FC/UPC-FC/APC

Tính năng:

Dây nhảy quang FC/UPC-FC/APC, Simplex 5M
Hãng sản xuất : Kington
Xuất xứ : Chính hãng , sản xuất : Trung quốc
Mã sản phẩm : MIS-005-969
Loại sản phẩm : Dây nhẩy quang Sigle mode
Tính năng : Dây nhảy quang nối 2 đầu cáp quang
Chiều dài : 5M
Đầu kết nối : FC/PC-FC/APC

Dây nhảy quang FC/UPC-FC/APC, Simplex 5M

Dây nhảy quang SC-LC, Simplex

Giá: Call

Mã SP: SC-LC

Tính năng:

 

Detailed Product Description
Description
Fiber Optic Patch cords are ultra reliable components featuring low insertion loss and return loss. They come with your choice of simplex or duplex cable configuration and are made to conform to IEC,Telcordia GR-326-CORE Standard.
Environmental Reliability Test
The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others
Key Features
Low insertion loss
Low return loss
Various connector types available
Easy instalation
Environmentally stable
Applications
Fiber Optic Telecommunications
LAN (Local Area Network
FTTH (Fiber To The Home)
CATV&CCTV
High speed transmission systems
Fiber optic sensing
Specifications
Type
Standard,Master
Style
LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC 
Duplex MTRJ/Female, MTRJ/Male
Fiber Type
 
9/125 SMF-28 or equivalent (Singlemade) OS1
50/125, 62.5/125 (Multimode) OM2&OM1
50/125, 10G (Multimode) OM3
Cable Type
Simplex, Duplex (Zipcord)
Φ3.0mm, Φ2.0mm, Φ1.8mm
Φ1.6mm PVC or LSZH
Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH
Polishing Manner
UPC,SPC,APC (8°& 6°)
Insertion Loss
≤ 0.1dB (For Singlemode Master)
≤ 0.25dB (For Singlemode Standard)
≤ 0.25dB (For Multimode)
Tested by JDS RM 3750
Return Loss
(For Singlemode)
UPC ≥ 50dB
SPC ≥ 55dB
APC ≥ 60dB (typ.65dB)
Tested by JDS RM3750
Repeatability
 
±0.1dB
Operating temperature
-400C to 850C
Geometry Requirement
(For Singlemode)
Ferrule Endface Radius
7mm ≤ R ≤ 12mm (For APC)
10mm ≤ R ≤ 25mm (For Standard)
Apex Offset ≤ 30 μm (For Master)
Apex Offset ≤ 50 μm (For Standard)
Undercut -50nm ≤ U ≤ 50nm
Tested by DORC ZX-1

Dây nhảy quang SC-LC, Simplex

Dây nhảy quang LC-LC, Simplex

Giá: Call

Mã SP: LC-LC

Tính năng:

 

Detailed Product Description
 
LC Fiber patch cord 
 
Description
Fiber optic Patch cords are ultra reliable components featuring low insertion loss and return loss. They come with your choice of si mplex or duplex cable configuration and are made to conform to IEC,Telcordia GR-326-CORE Standard.
Environmental Reliability Test
The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others
Key Features
Low insertion loss
Low return loss
Various connector types available
Easy instalation
Environmentally stable
Applications
Fiber Optic Telecommunications
LAN (Local Area Network
FTTH (Fiber To The Home)
CATV&CCTV
High speed transmission systems
Fiber optic sensing
Specifications
Type
Standard,Master
Style
LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC 
Duplex MTRJ/Female, MTRJ/Male
Fiber Type
 
9/125 SMF-28 or equivalent (Singlemade) OS1
50/125, 62.5/125 (Multimode) OM2&OM1
50/125, 10G (Multimode) OM3
Cable Type
Simplex, Duplex (Zipcord)
Φ3.0mm, Φ2.0mm, Φ1.8mm
Φ1.6mm PVC or LSZH
Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH
Polishing Manner
UPC,SPC,APC (8°& 6°)
Insertion Loss
≤ 0.1dB (For Singlemode Master)
≤ 0.25dB (For Singlemode Standard)
≤ 0.25dB (For Multimode)
Tested by JDS RM 3750
Return Loss
(For Singlemode)
UPC ≥ 50dB
SPC ≥ 55dB
APC ≥ 60dB (typ.65dB)
Tested by JDS RM3750
Repeatability
 
±0.1dB
Operating temperature
-400C to 850C
Geometry Requirement
(For Singlemode)
Ferrule Endface Radius
7mm ≤ R ≤ 12mm (For APC)
10mm ≤ R ≤ 25mm (For Standard)
Apex Offset ≤ 30 μm (For Master)
Apex Offset ≤ 50 μm (For Standard)
Undercut -50nm ≤ U ≤ 50nm
Tested by DORC ZX-1

Dây nhảy quang LC-LC, Simplex

Dây nhảy quang FC-LC, Simplex

Giá: Call

Mã SP: FC-LC

Tính năng:

 

Detailed Product Description
 
FC/LC Fiber optic patchcord
Description
FC/LC FIBER OPTIC JUMPERS are ultra reliable components featuring low insertion loss and high return loss. They come with your choice of simplex or duplex cable configuration and are made to conform to IEC,Telcordia GR-326-CORE Standard.
Environmental Reliability Test
The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others
Key Features
Low insertion loss
high return loss
Various connector types available
Easy instalation
Environmentally stable
Applications
Fiber Optic Telecommunications
LAN (Local Area Network
FTTH (Fiber To The Home)
CATV&CCTV
High speed transmission systems
Fiber optic sensing
Specifications
Type
Standard,Master
Style
LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC 
Duplex MTRJ/Female, MTRJ/Male FIBER PATCH CORD OR FIBER OPTIC PATCH CORD OR FIBEROPTIC CABLE
Fiber Type
 
9/125 SMF-28 or equivalent (Singlemade) OS1
50/125, 62.5/125 (Multimode) OM2&OM1
50/125, 10G (Multimode) OM3
Fiber Cable Type
Simplex, Duplex (Zipcord)
Φ3.0mm, Φ2.0mm, Φ1.8mm
Φ1.6mm PVC or LSZH
Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH
Polishing Manner
UPC,SPC,APC (8°& 6°)
Insertion Loss
≤ 0.1dB (For Singlemode Master)
≤ 0.25dB (For Singlemode Standard)
≤ 0.25dB (For Multimode)
Tested by JDS RM 3750
Return Loss
(For Singlemode)
UPC ≥ 50dB
SPC ≥ 55dB
APC ≥ 60dB (typ.65dB)
Tested by JDS RM3750
Repeatability
 
±0.1dB
Operating temperature
-400C to 850C
Geometry Requirement
(For Singlemode)
Ferrule Endface Radius
7mm ≤ R ≤ 12mm (For APC)
10mm ≤ R ≤ 25mm (For Standard)
Apex Offset ≤ 30 μm (For Master)
Apex Offset ≤ 50 μm (For Standard)
Undercut -50nm ≤ U ≤ 50nm
Tested by DORC ZX-1

Dây nhảy quang FC-LC, Simplex

Dây nhảy quang SC-FC, Simplex

Giá: Call

Mã SP: SC-FC

Tính năng:

 

Detailed Product Description
 
FC/SC Fiber optic patchcord 
 
Description
FC/SC FIBER OPTIC JUMPERS are ultra reliable components featuring low insertion loss and high return loss. They come with your choice of simplex or duplex cable configuration and are made to conform to IEC,Telcordia GR-326-CORE Standard.
Environmental Reliability Test
The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others
Key Features
Low insertion loss
high return loss
Various connector types available
Easy instalation
Environmentally stable
Applications
Fiber Optic Telecommunications
LAN (Local Area Network
FTTH (Fiber To The Home)
CATV&CCTV
High speed transmission systems
Fiber optic sensing
Specifications
Type
Standard,Master
Style
LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC 
Duplex MTRJ/Female, MTRJ/Male FIBER PATCH CORD OR FIBER OPTIC PATCH CORD OR FIBEROPTIC CABLE
Fiber Type
 
9/125 SMF-28 or equivalent (Singlemade) OS1
50/125, 62.5/125 (Multimode) OM2&OM1
50/125, 10G (Multimode) OM3
Fiber Cable Type
Simplex, Duplex (Zipcord)
Φ3.0mm, Φ2.0mm, Φ1.8mm
Φ1.6mm PVC or LSZH
Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH
Polishing Manner
UPC,SPC,APC (8°& 6°)
Insertion Loss
≤ 0.1dB (For Singlemode Master)
≤ 0.25dB (For Singlemode Standard)
≤ 0.25dB (For Multimode)
Tested by JDS RM 3750
Return Loss
(For Singlemode)
UPC ≥ 50dB
SPC ≥ 55dB
APC ≥ 60dB (typ.65dB)
Tested by JDS RM3750
Repeatability
 
±0.1dB
Operating temperature
-400C to 850C
Geometry Requirement
(For Singlemode)
Ferrule Endface Radius
7mm ≤ R ≤ 12mm (For APC)
10mm ≤ R ≤ 25mm (For Standard)
Apex Offset ≤ 30 μm (For Master)
Apex Offset ≤ 50 μm (For Standard)
Undercut -50nm ≤ U ≤ 50nm
Tested by DORC ZX-1

Dây nhảy quang SC-FC, Simplex

Dây nhảy quang ST-ST,Multimode Duplex

Giá: Call

Mã SP: ST-ST

Tính năng:

 

Detailed Product Description
 
ST Patch cord 
A patch cord can be split into three key components; 
the connector 
the cable 
the manufacturing process. 
 
Description
Fiber Optic Patch cords are ultra reliable components featuring low insertion loss and return loss. They come with your choice of simplex or duplex cable configuration and are made to conform to IEC,Telcordia GR-326-CORE Standard.
Environmental Reliability Test
The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others
Key Features
Low insertion loss
Low return loss
Various connector types available
Easy instalation
Environmentally stable
Applications
Fiber Optic Telecommunications
LAN (Local Area Network
FTTH (Fiber To The Home)
CATV&CCTV
High speed transmission systems
Fiber optic sensing
Specifications
Type
Standard,Master
Style
LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC 
Duplex MTRJ/Female, MTRJ/Male
Fiber Type
 
9/125 SMF-28 or equivalent (Singlemade) OS1
50/125, 62.5/125 (Multimode) OM2&OM1
50/125, 10G (Multimode) OM3
Cable Type
Simplex, Duplex (Zipcord)
Φ3.0mm, Φ2.0mm, Φ1.8mm
Φ1.6mm PVC or LSZH
Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH
Polishing Manner
UPC,SPC,APC (8°& 6°)
Insertion Loss
≤ 0.1dB (For Singlemode Master)
≤ 0.25dB (For Singlemode Standard)
≤ 0.25dB (For Multimode)
Tested by JDS RM 3750
Return Loss
(For Singlemode)
UPC ≥ 50dB
SPC ≥ 55dB
APC ≥ 60dB (typ.65dB)
Tested by JDS RM3750
Repeatability
 
±0.1dB
Operating temperature
-400C to 850C
Geometry Requirement
(For Singlemode)
Ferrule Endface Radius
7mm ≤ R ≤ 12mm (For APC)
10mm ≤ R ≤ 25mm (For Standard)
Apex Offset ≤ 30 μm (For Master)
Apex Offset ≤ 50 μm (For Standard)
Undercut -50nm ≤ U ≤ 50nm
Tested by DORC ZX-1

Dây nhảy quang ST-ST,Multimode Duplex

Dây nhảy quang SC-SC, Simplex

Giá: Call

Mã SP: SC-SC

Tính năng:

 

Detailed Product Description
 
SC Fiber patch cord 
 
Description
Fiber optic Patch cords are ultra reliable components featuring low insertion loss and return loss. They come with your choice of si mplex or duplex cable configuration and are made to conform to IEC,Telcordia GR-326-CORE Standard.
Environmental Reliability Test
The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others
Key Features
Low insertion loss
Low return loss
Various connector types available
Easy instalation
Environmentally stable
Applications
Fiber Optic Telecommunications
LAN (Local Area Network
FTTH (Fiber To The Home)
CATV&CCTV
High speed transmission systems
Fiber optic sensing
Specifications
Type
Standard,Master
Style
LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC 
Duplex MTRJ/Female, MTRJ/Male
Fiber Type
 
9/125 SMF-28 or equivalent (Singlemade) OS1
50/125, 62.5/125 (Multimode) OM2&OM1
50/125, 10G (Multimode) OM3
Cable Type
Simplex, Duplex (Zipcord)
Φ3.0mm, Φ2.0mm, Φ1.8mm
Φ1.6mm PVC or LSZH
Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH
Polishing Manner
UPC,SPC,APC (8°& 6°)
Insertion Loss
≤ 0.1dB (For Singlemode Master)
≤ 0.25dB (For Singlemode Standard)
≤ 0.25dB (For Multimode)
Tested by JDS RM 3750
Return Loss
(For Singlemode)
UPC ≥ 50dB
SPC ≥ 55dB
APC ≥ 60dB (typ.65dB)
Tested by JDS RM3750
Repeatability
 
±0.1dB
Operating temperature
-400C to 850C
Geometry Requirement
(For Singlemode)
Ferrule Endface Radius
7mm ≤ R ≤ 12mm (For APC)
10mm ≤ R ≤ 25mm (For Standard)
Apex Offset ≤ 30 μm (For Master)
Apex Offset ≤ 50 μm (For Standard)
Undercut -50nm ≤ U ≤ 50nm
Tested by DORC ZX-1

Dây nhảy quang SC-SC, Simplex

Dây nhảy quang FC-FC, Simplex

Giá: Call

Mã SP: FC-FC

Tính năng:

 

Detailed Product Description
 
FC/FC Fiber optic cable 
 
 
Description
FIBER OPTIC JUMPERS are ultra reliable components featuring low insertion loss and return loss. They come with your choice of simplex or duplex cable configuration and are made to conform to IEC,Telcordia GR-326-CORE Standard.
Environmental Reliability Test
The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others
Key Features
Low insertion loss
high return loss
Various connector types available
Easy instalation
Environmentally stable
Applications
Fiber Optic Telecommunications
LAN (Local Area Network
FTTH (Fiber To The Home)
CATV&CCTV
High speed transmission systems
Fiber optic sensing
Specifications
Type
Standard,Master
Style
LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC 
Duplex MTRJ/Female, MTRJ/Male FIBER PATCH CORD OR FIBER OPTIC PATCH CORD OR FIBEROPTIC CABLE
Fiber Type
 
9/125 SMF-28 or equivalent (Singlemade) OS1
50/125, 62.5/125 (Multimode) OM2&OM1
50/125, 10G (Multimode) OM3
Fiber Cable Type
Simplex, Duplex (Zipcord)
Φ3.0mm, Φ2.0mm, Φ1.8mm
Φ1.6mm PVC or LSZH
Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH
Polishing Manner
UPC,SPC,APC (8°& 6°)
Insertion Loss
≤ 0.1dB (For Singlemode Master)
≤ 0.25dB (For Singlemode Standard)
≤ 0.25dB (For Multimode)
Tested by JDS RM 3750
Return Loss
(For Singlemode)
UPC ≥ 50dB
SPC ≥ 55dB
APC ≥ 60dB (typ.65dB)
Tested by JDS RM3750
Repeatability
 
±0.1dB
Operating temperature
-400C to 850C
Geometry Requirement
(For Singlemode)
Ferrule Endface Radius
7mm ≤ R ≤ 12mm (For APC)
10mm ≤ R ≤ 25mm (For Standard)
Apex Offset ≤ 30 μm (For Master)
Apex Offset ≤ 50 μm (For Standard)
Undercut -50nm ≤ U ≤ 50nm
Tested by DORC ZX-1