Giỏ hàng của bạn
Bạn chưa chọn sản phẩm nào..!
Danh mục sản phẩm
- Dịch vụ cho thuê (6)
- Dịch vụ sửa chữa bảo hành (8)
- Linh kiện máy tính (72)
-
Linh kiện server
(597)
- Bộ Nguồn Server Power Supply (183)
- Backplane Board (4)
- Extender Card (2)
- Mainboard (73)
- Tape Drive (1)
- Server Raid Controller (104)
- Hard Drives (107)
- CPU Upgraded (0)
- Memory (46)
- HDD Tray (15)
- Pan System (30)
- Memory Board (5)
- Heatsink VMR (3)
- Riser Card ,Riser Board (6)
- Rack Rail Kits (5)
- Acessories (12)
- HDD Backplane (5)
- Phần mềm (10)
- Thiết bị an ninh (25)
- Thiết bị lưu điện ups (196)
- Thiết bị firewall (23)
-
Thiết bị lưu trữ
(72)
-
Tape Cartridge (39)
- IBM Data Cartridge (2)
- LTO Ultrium 1,2,3,4,5 (17)
- 4mm DDS5 DAT72 (4)
- 4mm DDS Tape (8)
- 8mm Tape (0)
- AIT Tape (0)
- DDS Tape (0)
- DLT Tape (3)
- SDLT Tape (4)
- Travan Tape (0)
- VXA Tape (0)
- Magstar 3570,3590 Cartridges (0)
- 3592 Cartridges (0)
- Optical Cartridges (0)
- RDX Cartridges (0)
- Travan Cartridges (0)
- Cleaning Cartridges (1)
- Tape Library Controller Card (1)
- Nguồn Tape Library (1)
- Thiết bị Tape Driver (4)
- Thiết bị Nas Storage (27)
-
Tape Cartridge (39)
- Thiết bị mạng (547)
- Thiết bị máy tính (17)
- Thiết bị siêu thị (33)
- Thiết bị Server (44)
- Thiết bị văn phòng (94)
- Thiết bị wifi (171)
- Thiết bị ngân hàng (22)
- Thiết bị viễn thông (0)
- Cable (31)
- Thiết bị khác (38)
Hổ trợ online
Tin tức
Sản phẩm nổi bật
Thống kê truy cập
Dây nhảy quang MM,SC-LC, Duplex
- Chi tiết
- Thông số kỹ thuật
- Download
- Phản hồi khách hàng
Sản phẩm cùng loại
Dây nhảy quang MM,ST-LC, Duplex
Detailed Product Description ST-LC Multimode Patch cord, Duplex A patch cord can be split into three key components; the connector the cable the manufacturing process. Description Fiber Optic Patch cords are ultra reliable components featuring low insertion loss and return loss. They come with your choice of simplex or duplex cable configuration and are made to conform to IEC,Telcordia GR-326-CORE Standard. Environmental Reliability Test The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others Key Features Low insertion loss Low return loss Various connector types available Easy instalation Environmentally stable Applications Fiber Optic Telecommunications LAN (Local Area Network FTTH (Fiber To The Home) CATV&CCTV High speed transmission systems Fiber optic sensing Specifications Type Standard,Master Style LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC Duplex MTRJ/Female, MTRJ/Male Fiber Type 9/125 SMF-28 or equivalent (Singlemade) OS1 50/125, 62.5/125 (Multimode) OM2&OM1 50/125, 10G (Multimode) OM3 Cable Type Simplex, Duplex (Zipcord) Φ3.0mm, Φ2.0mm, Φ1.8mm Φ1.6mm PVC or LSZH Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH Polishing Manner UPC,SPC,APC (8°& 6°) Insertion Loss ≤ 0.1dB (For Singlemode Master) ≤ 0.25dB (For Singlemode Standard) ≤ 0.25dB (For Multimode) Tested by JDS RM 3750 Return Loss (For Singlemode) UPC ≥ 50dB SPC ≥ 55dB APC ≥ 60dB (typ.65dB) Tested by JDS RM3750 Repeatability ±0.1dB Operating temperature -400C to 850C Geometry Requirement (For Singlemode) Ferrule Endface Radius 7mm ≤ R ≤ 12mm (For APC) 10mm ≤ R ≤ 25mm (For Standard) Apex Offset ≤ 30 μm (For Master) Apex Offset ≤ 50 μm (For Standard) Undercut -50nm ≤ U ≤ 50nm Tested by DORC ZX-1
3970 lượt xem
Mã SP: MM,ST-LC
Dây nhảy quang MM,LC-LC, Duplex
LC/LC Fiber optic patchcord Duplex Description LC/LC FIBER OPTIC JUMPERS are ultra reliable components featuring low insertion loss and high return loss. They come with your choice of simplex or duplex cable configuration and are made to conform to IEC,Telcordia GR-326-CORE Standard. Envronmental Reliability Test The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others Key Features Low insertion loss high return loss Various connector types available Easy instalation Environmentally stable Applications Fiber Optic Telecommunications LAN (Local Area Network FTTH (Fiber To The Home) CATV&CCTV High speed transmission systems Fiber optic sensing Specifications Type Standard,Master Style LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC Duplex MTRJ/Female, MTRJ/Male FIBER PATCH CORD OR FIBER OPTIC PATCH CORD OR FIBEROPTIC CABLE Fiber Type 9/125 SMF-28 or equivalent (Singlemade) OS1 50/125, 62.5/125 (Multimode) OM2&OM1 50/125, 10G (Multimode) OM3 Fiber Cable Type Simplex, Duplex (Zipcord) Φ3.0mm, Φ2.0mm, Φ1.8mm Φ1.6mm PVC or LSZH Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH Polishing Manner UPC,SPC,APC (8°& 6°) Insertion Loss ≤ 0.1dB (For Singlemode Master) ≤ 0.25dB (For Singlemode Standard) ≤ 0.25dB (For Multimode) Tested by JDS RM 3750 Return Loss (For Singlemode) UPC ≥ 50dB SPC ≥ 55dB APC ≥ 60dB (typ.65dB) Tested by JDS RM3750 Repeatability ±0.1dB Operating temperature -400C to 850C Geometry Requirement (For Singlemode) Ferrule Endface Radius 7mm ≤ R ≤ 12mm (For APC) 10mm ≤ R ≤ 25mm (For Standard) Apex Offset ≤ 30 μm (For Master) Apex Offset ≤ 50 μm (For Standard) Undercut -50nm ≤ U ≤ 50nm Tested by DORC ZX-1
3822 lượt xem
Mã SP: MM,LC-LC
Dây nhảy quang MM,SC-SC, Duplex
Detailed Product Description SC/SC Fiber patch cord, Duplex Description Fiber optic Patch cords are ultra reliable components featuring low insertion loss and return loss. They come with your choice of si mplex or duplex cable configuration and are made to conform to IEC,Telcordia GR-326-CORE Standard. Environmental Reliability Test The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others Applications Fiber Optic Telecommunications LAN (Local Area Network FTTH (Fiber To The Home) CATV&CCTV High speed transmission systems Fiber optic sensing Specifications Type Standard,Master Style LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC Duplex MTRJ/Female, MTRJ/Male Fiber Type 9/125 SMF-28 or equivalent (Singlemade) OS1 50/125, 62.5/125 (Multimode) OM2&OM1 50/125, 10G (Multimode) OM3 Cable Type Simplex, Duplex (Zipcord) Φ3.0mm, Φ2.0mm, Φ1.8mm Φ1.6mm PVC or LSZH Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH Polishing Manner UPC,SPC,APC (8°& 6°) Insertion Loss ≤ 0.1dB (For Singlemode Master) ≤ 0.25dB (For Singlemode Standard) ≤ 0.25dB (For Multimode) Tested by JDS RM 3750 Return Loss (For Singlemode) UPC ≥ 50dB SPC ≥ 55dB APC ≥ 60dB (typ.65dB) Tested by JDS RM3750 Repeatability ±0.1dB Operating temperature -400C to 850C Geometry Requirement (For Singlemode) Ferrule Endface Radius 7mm ≤ R ≤ 12mm (For APC) 10mm ≤ R ≤ 25mm (For Standard) Apex Offset ≤ 30 μm (For Master) Apex Offset ≤ 50 μm (For Standard) Undercut -50nm ≤ U ≤ 50nm Tested by DORC ZX-1
3855 lượt xem
Mã SP: MM,SC-SC
Dây nhảy quang MM,SC-LC, Duplex
Detailed Product Description SC/LC Fiber optic patchcord Duplex Description SC/LC FIBER OPTIC JUMPERS are ultra reliable components featuring low insertion loss and high return loss. They come with your choice of simplex or duplex cable configuration and are made to conform to IEC,Telcordia GR-326-CORE Standard. Envronmental Reliability Test The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others Key Features Low insertion loss high return loss Various connector types available Easy instalation Environmentally stable Applications Fiber Optic Telecommunications LAN (Local Area Network FTTH (Fiber To The Home) CATV&CCTV High speed transmission systems Fiber optic sensing Specifications Type Standard,Master Style LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC Duplex MTRJ/Female, MTRJ/Male FIBER PATCH CORD OR FIBER OPTIC PATCH CORD OR FIBEROPTIC CABLE Fiber Type 9/125 SMF-28 or equivalent (Singlemade) OS1 50/125, 62.5/125 (Multimode) OM2&OM1 50/125, 10G (Multimode) OM3 Fiber Cable Type Simplex, Duplex (Zipcord) Φ3.0mm, Φ2.0mm, Φ1.8mm Φ1.6mm PVC or LSZH Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH Polishing Manner UPC,SPC,APC (8°& 6°) Insertion Loss ≤ 0.1dB (For Singlemode Master) ≤ 0.25dB (For Singlemode Standard) ≤ 0.25dB (For Multimode) Tested by JDS RM 3750 Return Loss (For Singlemode) UPC ≥ 50dB SPC ≥ 55dB APC ≥ 60dB (typ.65dB) Tested by JDS RM3750 Repeatability ±0.1dB Operating temperature -400C to 850C Geometry Requirement (For Singlemode) Ferrule Endface Radius 7mm ≤ R ≤ 12mm (For APC) 10mm ≤ R ≤ 25mm (For Standard) Apex Offset ≤ 30 μm (For Master) Apex Offset ≤ 50 μm (For Standard) Undercut -50nm ≤ U ≤ 50nm Tested by DORC ZX-1
3828 lượt xem
Mã SP: MM,SC-LC
Dây Pigtail ST, Multimode
Detailed Product Description FC SC LC ST optic fiber pigtail Description Single mode pigtail Available in: SPC (Super Physical Contact), UPC (Ultra Physical Contact) or APC (Angled Physical Contact) Fiber type: G652.D, G655 and G657.A Construction of secondary protection: tight or loose Available in 12 colours of primary and secondary protection Multi mode pigtail Fiber types: OM1, OM2 and OM3 Construction of secondary protection: tight or loose Available in 12 colours of primary and secondary protection Environmental Reliability Test The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others Key Features Low insertion loss Low return loss Various connector types available Easy instalation Environmentally stable Applications Fiber Optic Telecommunications LAN (Local Area Network FTTH (Fiber To The Home) CATV&CCTV High speed transmission systems Fiber optic sensing Specifications Type Standard,Master Style LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC Duplex MTRJ/Female, MTRJ/Male Fiber Type 9/125 SMF-28 or equivalent (Singlemade) OS1 50/125, 62.5/125 (Multimode) OM2&OM1 50/125, 10G (Multimode) OM3 Cable Type Simplex, Duplex (Zipcord) Φ3.0mm, Φ2.0mm, Φ1.8mm Φ1.6mm PVC or LSZH Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH Polishing Manner UPC,SPC,APC (8°& 6°) Insertion Loss ≤ 0.1dB (For Singlemode Master) ≤ 0.25dB (For Singlemode Standard) ≤ 0.25dB (For Multimode) Tested by JDS RM 3750 Return Loss (For Singlemode) UPC ≥ 50dB SPC ≥ 55dB APC ≥ 60dB (typ.65dB) Tested by JDS RM3750 Repeatability ±0.1dB Operating temperature -400C to 850C Geometry Requirement (For Singlemode) Ferrule Endface Radius 7mm ≤ R ≤ 12mm (For APC) 10mm ≤ R ≤ 25mm (For Standard) Apex Offset ≤ 30 μm (For Master) Apex Offset ≤ 50 μm (For Standard) Undercut -50nm ≤ U ≤ 50nm Tested by DORC ZX-1
3905 lượt xem
Mã SP: Pigtail ST
Dây Pigtail LC, Singlemode
Detailed Product Description LC fiber optic pigtail Description Single mode pigtail Available in: SPC (Super Physical Contact), UPC (Ultra Physical Contact) or APC (Angled Physical Contact) Fiber type: G652.D, G655 and G657.A Construction of secondary protection: tight or loose Available in 12 colours of primary and secondary protection Multi mode pigtail Fiber types: OM1, OM2 and OM3 Construction of secondary protection: tight or loose Available in 12 colours of primary and secondary protection Environmental Reliability Test The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others Key Features Low insertion loss Low return loss Various connector types available Easy instalation Environmentally stable Applications Fiber Optic Telecommunications LAN (Local Area Network FTTH (Fiber To The Home) CATV&CCTV High speed transmission systems Fiber optic sensing Specifications Type Standard,Master Style LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC Duplex MTRJ/Female, MTRJ/Male Fiber Type 9/125 SMF-28 or equivalent (Singlemade) OS1 50/125, 62.5/125 (Multimode) OM2&OM1 50/125, 10G (Multimode) OM3 Cable Type Simplex, Duplex (Zipcord) Φ3.0mm, Φ2.0mm, Φ1.8mm Φ1.6mm PVC or LSZH Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH Polishing Manner UPC,SPC,APC (8°& 6°) Insertion Loss ≤ 0.1dB (For Singlemode Master) ≤ 0.25dB (For Singlemode Standard) ≤ 0.25dB (For Multimode) Tested by JDS RM 3750 Return Loss (For Singlemode) UPC ≥ 50dB SPC ≥ 55dB APC ≥ 60dB (typ.65dB) Tested by JDS RM3750 Repeatability ±0.1dB Operating temperature -400C to 850C Geometry Requirement (For Singlemode) Ferrule Endface Radius 7mm ≤ R ≤ 12mm (For APC) 10mm ≤ R ≤ 25mm (For Standard) Apex Offset ≤ 30 μm (For Master) Apex Offset ≤ 50 μm (For Standard) Undercut -50nm ≤ U ≤ 50nm Tested by DORC ZX-1
3845 lượt xem
Mã SP: Pigtail LC
Dây Pigtail FC, Singlemode
Detailed Product Description FC fiber optic pigtails Description Single mode pigtails Available in: SPC (Super Physical Contact), UPC (Ultra Physical Contact) or APC (Angled Physical Contact) Fiber type: G652.D, G655 and G657.A Construction of secondary protection: tight or loose Available in 12 colours of primary and secondary protection Multi mode pigtails Fiber types: OM1, OM2 and OM3 Construction of secondary protection: tight or loose Available in 12 colours of primary and secondary protection Environmental Reliability Test The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others Key Features Low insertion loss Low return loss Various connector types available Easy instalation Environmentally stable Applications Fiber Optic Telecommunications LAN (Local Area Network FTTH (Fiber To The Home) CATV&CCTV High speed transmission systems Fiber optic sensing Specifications Type Standard,Master Style LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC Duplex MTRJ/Female, MTRJ/Male Fiber Type 9/125 SMF-28 or equivalent (Singlemade) OS1 50/125, 62.5/125 (Multimode) OM2&OM1 50/125, 10G (Multimode) OM3 Cable Type Simplex, Duplex (Zipcord) Φ3.0mm, Φ2.0mm, Φ1.8mm Φ1.6mm PVC or LSZH Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH Polishing Manner UPC,SPC,APC (8°& 6°) Insertion Loss ≤ 0.1dB (For Singlemode Master) ≤ 0.25dB (For Singlemode Standard) ≤ 0.25dB (For Multimode) Tested by JDS RM 3750 Return Loss (For Singlemode) UPC ≥ 50dB SPC ≥ 55dB APC ≥ 60dB (typ.65dB) Tested by JDS RM3750 Repeatability ±0.1dB Operating temperature -400C to 850C Geometry Requirement (For Singlemode) Ferrule Endface Radius 7mm ≤ R ≤ 12mm (For APC) 10mm ≤ R ≤ 25mm (For Standard) Apex Offset ≤ 30 μm (For Master) Apex Offset ≤ 50 μm (For Standard) Undercut -50nm ≤ U ≤ 50nm Tested by DORC ZX-1
3762 lượt xem
Mã SP: Pigtail FC
Dây Pigtail SC, Singlemode
Detailed Product Description SC fiber optic pigtails Description Single mode pigtails Available in: SPC (Super Physical Contact), UPC (Ultra Physical Contact) or APC (Angled Physical Contact) Fiber type: G652.D, G655 and G657.A Construction of secondary protection: tight or loose Available in 12 colours of primary and secondary protection Multi mode pigtails Fiber types: OM1, OM2 and OM3 Construction of secondary protection: tight or loose Available in 12 colours of primary and secondary protection Environmental Reliability Test The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others Key Features Low insertion loss Low return loss Various connector types available Easy instalation Environmentally stable Applications Fiber Optic Telecommunications LAN (Local Area Network FTTH (Fiber To The Home) CATV&CCTV High speed transmission systems Fiber optic sensing Specifications Type Standard,Master Style LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC Duplex MTRJ/Female, MTRJ/Male Fiber Type 9/125 SMF-28 or equivalent (Singlemade) OS1 50/125, 62.5/125 (Multimode) OM2&OM1 50/125, 10G (Multimode) OM3 Cable Type Simplex, Duplex (Zipcord) Φ3.0mm, Φ2.0mm, Φ1.8mm Φ1.6mm PVC or LSZH Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH Polishing Manner UPC,SPC,APC (8°& 6°) Insertion Loss ≤ 0.1dB (For Singlemode Master) ≤ 0.25dB (For Singlemode Standard) ≤ 0.25dB (For Multimode) Tested by JDS RM 3750 Return Loss (For Singlemode) UPC ≥ 50dB SPC ≥ 55dB APC ≥ 60dB (typ.65dB) Tested by JDS RM3750 Repeatability ±0.1dB Operating temperature -400C to 850C Geometry Requirement (For Singlemode) Ferrule Endface Radius 7mm ≤ R ≤ 12mm (For APC) 10mm ≤ R ≤ 25mm (For Standard) Apex Offset ≤ 30 μm (For Master) Apex Offset ≤ 50 μm (For Standard) Undercut -50nm ≤ U ≤ 50nm Tested by DORC ZX-1
3635 lượt xem
Mã SP: Pigtail SC
Dây nhảy quang Multimode SC-SC, Simplex
Detailed Product Description SC Fiber patch cord Description Fiber optic Patch cords are ultra reliable components featuring low insertion loss and return loss. They come with your choice of si mplex or duplex cable configuration and are made to conform to IEC,Telcordia GR-326-CORE Standard. Environmental Reliability Test The performance of the patchcords has been carefully designed to meet the IEC standards, GR-326-CORE, in the test of optical characteristics, vibration test, thermal cycling, impact resistance, salt spray erosion, thermal aging, humidity resistance and others Applications Fiber Optic Telecommunications LAN (Local Area Network FTTH (Fiber To The Home) CATV&CCTV High speed transmission systems Fiber optic sensing Specifications Type Standard,Master Style LC,SC,ST,FC.MU,DIN,D4,MPO, SC/APC,FC/APC,LC/APC.MU/APC Duplex MTRJ/Female, MTRJ/Male Fiber Type 9/125 SMF-28 or equivalent (Singlemade) OS1 50/125, 62.5/125 (Multimode) OM2&OM1 50/125, 10G (Multimode) OM3 Cable Type Simplex, Duplex (Zipcord) Φ3.0mm, Φ2.0mm, Φ1.8mm Φ1.6mm PVC or LSZH Φ0.9mm, Φ0.6mm buffered fiber PVC or LSZH Polishing Manner UPC,SPC,APC (8°& 6°) Insertion Loss ≤ 0.1dB (For Singlemode Master) ≤ 0.25dB (For Singlemode Standard) ≤ 0.25dB (For Multimode) Tested by JDS RM 3750 Return Loss (For Singlemode) UPC ≥ 50dB SPC ≥ 55dB APC ≥ 60dB (typ.65dB) Tested by JDS RM3750 Repeatability ±0.1dB Operating temperature -400C to 850C Geometry Requirement (For Singlemode) Ferrule Endface Radius 7mm ≤ R ≤ 12mm (For APC) 10mm ≤ R ≤ 25mm (For Standard) Apex Offset ≤ 30 μm (For Master) Apex Offset ≤ 50 μm (For Standard) Undercut -50nm ≤ U ≤ 50nm Tested by DORC ZX-1
3885 lượt xem
Mã SP: Multimode SC-SC